콘텐츠로 이동

Troubleshooting

이 콘텐츠는 아직 번역되지 않았습니다.

Find your symptom in the table. For video problems, see No video.

SymptomCause and fix
Every page says NOT_PROVISIONEDThe device is not claimed yet. Read the setup code and claim it. See Quick start.
The setup code is rejectedIt works once, expires after 24 hours, and a restart of an unclaimed device makes a new one. Read the latest from ~/backend.log. After five wrong attempts the device answers 429 until it is restarted: run sudo systemctl restart edgevision-api, then read the new code.
journalctl -u edgevision-api is emptyExpected. The service writes to ~/backend.log instead.
~/backend.log is largeOnly an update rotates it, keeping one older copy. Between updates it grows. Check its size with ls -la ~/backend.log.
The service is running but does not start after a rebootCheck systemctl is-enabled edgevision-api. If it says anything but enabled, contact support to re-run the device setup.
Both built-in models show RegisteredTheir engine files are not on the device yet. Your installer places them, and the models become Ready after the service restarts. You can also upload your own model.